Product Details:
Payment & Shipping Terms:
|
Product Name: | 3-zone Thermal Shock Test Chamber | Interrior Material: | 600*500*500mm |
---|---|---|---|
Exterrior Material: | 1640*1890*1830mm | High Temp. Chamber: | +60 Oc~+200 Oc |
Low Temp. Chamber: | -70 Oc~-10 Oc | Pre-Heat Time: | +60 Oc~+200 Oc Within 20mins |
Pre-Cold Time: | +20 Oc~-70 Oc Within 60mins | Test Chamber: | -55 Oc~+150 Oc |
Usage: | Universal Testing Machine | Application: | Widely |
High Light: | temperature shock test chamber,thermal shock chamber |
CE Marked High and Low Temperature 3-Zone Thermal Shock Testing Chamber
Product Description
3-zone thermal shock testing chamberis also known as hot and cold impact testing machine, used to test
or composite material structure, in an instant by the extremely high temperature and low temperature under continuous environment can endure degree, in order to test in the shortest possible time chemical changes caused by heat bilges cold shrink or physical damage. Applicable to metal and plastic, rubber, electronic...Such as material, can be used as the basis of its product improvements or reference.
Applications
3-zone Thermal shock chamber have been designed to operate in accordance with reliability programs, quality control, commercial test programs and medical tests. It is used to test the capability of material structure or composite material to withstand the continuous environmental changes between extremely high temperature and low temperature during a short period. It is applicable to metals, plastic, rubber, electronics amongst other materials. The test result can be used as a reference or basis for produce improvement.
Features
1.Thermal shork chamber in each zone for peak demand of heating and cooling. Provides extra thermal energy to efficiently meet the MIL-STD 883 requirements.
2.Temperature recorder provides 24 hour part temperature recording as the load travels from zone to zone. Using touch-control graph control as operation interface, easy to operate.
3.The system can be used for automatic Circulation Shock or manual selective shock, capable of setting two zones or three zones shocks as well as cold and thermal shock start-up.
4.Custom-made and optional accessories available.
Standards Implement and Met
GB/T 2443.1-2001 Test A: Low temp. Test;
GB/T 2443.2-2001 Test B: Low temp. Test;
GB/T 2443.22-2002 Test N: Low temp. Test;
GJB 150.3-1986 High Temp. Test;
GJB 150.4-1986 Low temp. Test;
GJB 150.5-1986 Temp. Impact Test;
(Load refer to 5.5.5 no active load)
Working Principle
This is so called three-zone type thermal shock test chamber.
Sample is placed in the test chamber, more extreme temperature than test temperature can be set in high-temperature chamber and low-temperature chamber. When it comes to low temperature test, cold chamber door open, and low-temperature chamber working together with test chamber.
When converted into high-temperature test, cold chamber door closed, hot chamber door are opened, and test chamber working together with high-temperature chamber.
Conversion of mechanical action (transferring from high temperature to low temperature or low temperature to high temperature) can be completed in less than 1second, and the temperature can be quickly stabilized.
During the whole test, test sample is no need to be moved, and without any human intervention.
Specifications
Model |
|
|||||||||||||||
72B | 100B | 150B | 200B | 252B | 300B | 480B | ||||||||||
Interior size | W(mm) | 450 | 500 | 600 | 670 | 700 | 800 | 800 | ||||||||
H(mm) | 400 | 450 | 500 | 600 | 600 | 600 | 800 | |||||||||
D(mm) | 400 | 450 | 500 | 500 | 600 | 650 | 750 | |||||||||
Exterior size | W(mm) | 1490 | 1540 | 1640 | 1720 | 1750 | 1850 | 1850 | ||||||||
H(mm) | 1790 | 1840 | 1890 | 2000 | 2000 | 2000 | 2200 | |||||||||
D(mm) | 1600 | 1700 | 1830 | 1850 | 1930 | 1980 | 2500 | |||||||||
Test weight(KG) | 5 | 10 | 12 | 15 | 18 | 20 | 20 | |||||||||
Low Temp. chamber | -70ºC~-10ºC | |||||||||||||||
Pre-cooling time | +20ºC~-70ºC ,Within 60 min | |||||||||||||||
Test. chamber | -55ºC~+150ºC | |||||||||||||||
High Temp. chamber | +60ºC~+200ºC | |||||||||||||||
Pre-heating time | +60ºC~+200ºC ,Within 20 min | |||||||||||||||
Recovery time | High-Temp Exposure 30 min | |||||||||||||||
Low-Temp Exposure 30 min | ||||||||||||||||
Recovery time within 5 min | ||||||||||||||||
Safety device | No fuse breaker, over pressureover heat and over current protection for compressor,over temperature protection, over load protection for blower, dry heat protection | |||||||||||||||
Standard accessory | Cable port(portΦ50mm)*1, shelves*2 | |||||||||||||||
Interior material | Stainless steel plate(SUS 304) | |||||||||||||||
Exterior material | Baked painting steel or stainless steel(SUS304) | |||||||||||||||
Insulation material | Rigid polyurethane Foam+glass fiber wool | |||||||||||||||
Refrigeration system | Water Cooled | |||||||||||||||
Semi-hermetic compressor, cascade refrigeration system, CFC free refrigerant(HFC-507 and HFC-23) | ||||||||||||||||
Controller | Panel:7-inch LCD Touch panel,Chinese or English display selectable | |||||||||||||||
Operation model:Program or fix point running | ||||||||||||||||
Memory capacity:120programs,1200steps,all repeat 999cycles,part repeat 99 cycles. | ||||||||||||||||
Accuracy:Temp.:0.1% of F.S±1 digit Humidity:0.1% of F.S±1 digit | ||||||||||||||||
Input:Temp.:pt-100 Humidity:pt-100 or ~5V DCV | ||||||||||||||||
Ambient Temp. | +5ºC~+35ºC | |||||||||||||||
Power | AC 380±10%50Hz ,3 phase 4 wires +Ground Wires | |||||||||||||||
Note:1. We reserve the right to change specifications without prior notice 2. Customized sizes and configurations available |
Contact Person: Anna Hu
Tel: +8618098282716