Product Details:
Payment & Shipping Terms:
|
Usage: | Thermal Shock Tester | Ambient Temperature: | 0°~30° |
---|---|---|---|
Test Chamber Volume: | To Be Custom | Safty Device: | Earth Leakage Circuit Breaker |
Control: | PID | Preheating Temperature: | 50.00°C~220.00°C |
Temperature Uniformity: | ±2.00°C | Test Method: | GB/T 5170.2-2008 |
Heating Rate: | ≥17℃/min | Cooling Rate: | ≥3.7℃/min |
High Light: | temperature shock test chamber,environmental testing chambers |
Electronic High Accuracy Shock Thermal Air Test Chamber / Thermal Shock Tester
Product Introduction:
Thermal Shock Test Chamber is used to test the bearing extent of the material structures and composite material in an instant and continuous high temperature and extremely low temperature environment, which is in the shortest time to test its thermal expansion and contraction caused by chemical change or physical harm.
The equipment is widely used in metal, plastic, rubber, electronics and other materials and it can be used as an important reference for improving product quality. It meets the standard of MTL, IEC, JIS, GJB…
Features:
1. Perfect appearance and easy to operate.
2. Japan LCD English microcomputer temperature controller, with high memory capacity, can save 100 programs, max 9999 cycles, each cycle max time 999hrs.
3. Three chamber structures, high temperature chamber, low temperature chamber and test chamber, control automatically, stay and switch time adjustable.
4. Perfect protection alarm functions: short-circuits, Leakage, over temperature of work chamber; compressor over pressure, over load, short water…
5. Control interface will display alarm reason and provide check methods, machine has emergency stop button.
6. Cold and hot shock temperature recover within 5 minutes, which complies with MTL, IEC, JIS, GJB and other international standards.
7. With RS-232C communication port for connecting PC to control, record and save test report.
Specifications
(1) KTS-A Series
Model |
|
||||||||
72A | 100A | 150A | 200A | 252A | 300A | 480A | |||
Inside size(mm) | W | 450 | 500 | 600 | 670 | 700 | 800 | 800 | |
H | 400 | 450 | 500 | 600 | 600 | 600 | 800 | ||
D | 400 | 450 | 500 | 500 | 600 | 650 | 750 | ||
Outside size(mm) | W | 1490 | 1540 | 1640 | 1720 | 1750 | 1850 | 1850 | |
H | 1790 | 1840 | 1890 | 2000 | 2000 | 2000 | 2200 | ||
D | 1600 | 1700 | 1830 | 1850 | 1930 | 1980 | 2500 | ||
Test weight | 5 | 10 | 12 | 15 | 18 | 20 | 20 | ||
Low Temp Chamber | -55ºC~-10ºC, Pre cooling time: ≤ 60 min from +20ºCto-55ºC | ||||||||
Test Chamber | -40ºC~+150ºC | ||||||||
High Temp Chamber | +60ºC~+200ºC ,Within 20 min, Pre-heating time | ||||||||
Transition time | ≤15S | ||||||||
Recovery time | High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample | ||||||||
Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample | |||||||||
≤ 5 min | |||||||||
Ambient Temp. | +5ºC~+35ºC | ||||||||
Power | AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires |
(2) KTS-B Series
Model |
|
||||||||
72B | 100B | 150B | 200B | 252B | 300B | 480B | |||
Inside size(mm) | W | 450 | 500 | 600 | 670 | 700 | 800 | 800 | |
H | 400 | 450 | 500 | 600 | 600 | 600 | 800 |
D | 400 | 450 | 500 | 500 | 600 | 650 | 750 | |
Outside size(mm) | W | 1490 | 1540 | 1640 | 1720 | 1750 | 1850 | 1850 |
H | 1790 | 1840 | 1890 | 2000 | 2000 | 2000 | 2200 | |
D | 1600 | 1700 | 1830 | 1850 | 1930 | 1980 | 2500 | |
Test weight(KG) | 5 | 10 | 12 | 15 | 18 | 20 | 20 | |
Low Temp. chamber | -70ºC~-10ºC ,Pre cooling time: +20ºC~-70ºC ,≤ 60 min | |||||||
Test. Chamber | -55ºC~+150ºC | |||||||
High Temp. chamber temperature | +60ºC~+200ºC,Preheating time: ≤20 min | |||||||
Transition time | ≤15S | |||||||
Recovery time | High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample | |||||||
Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample | ||||||||
≤ 5 min | ||||||||
Ambient Temp. | +5ºC~+35ºC | |||||||
Power | AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires |
(3) KTS-D Series
Model |
|
||||||||
72D | 100D | 150D | 200D | 252D | 300D | 480D | |||
Inside size(mm) | W | 450 | 500 | 600 | 670 | 700 | 800 | 800 | |
H | 400 | 450 | 500 | 600 | 600 | 600 | 800 | ||
D | 400 | 450 | 500 | 500 | 600 | 650 | 750 | ||
Outside size(mm) | W | 1490 | 1540 | 1640 | 1720 | 1750 | 1850 | 1850 | |
H | 1790 | 1840 | 1890 | 2000 | 2000 | 2000 | 2200 | ||
D | 1600 | 1700 | 1830 | 1850 | 1930 | 1980 | 2500 | ||
Test weight | 5 | 10 | 12 | 15 | 18 | 20 | 20 | ||
Low Temp Chamber | -80ºC~-10ºC, Pre cooling time: ≤ 60 min from +20ºCto-80ºC |
Test Chamber | -65ºC~+150ºC |
High Temp Chamber | +60ºC~+200ºC ,Within 20 min, Pre-heating time |
Transition time | ≤15S |
Recovery time | High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample |
Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample | |
≤ 5 min | |
Ambient Temp. | +5ºC~+35ºC |
Power | AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires |
FAQ:
Why choose us?
1. Considerate Service Different countries plugs, manually change the-voltage from 110V to 220V, insurance indicator.
2.Excellent After sale Service:
12 months warranty. Besides, we can help you to repair your problem controller freely, Free replacement parts, even it's not from our factory's. What you need to do is to send us the controller.We can offer operation video and English operation muanual. We can provide video-con
3.Commitment:
We will sign a letter of commitment while we sign the contract, which will improve your confidence to us.
4.Good Packaging:
Simulation Animatronic Customer Triceratops are covered with air bubble film before put them into the wooden case, which not only has good shock absorption, impact resistance, heat sealing and also has the advantages of nontoxic, odorless, moisture corrosion, good transparency etc.
Contact Person: Anna Hu
Tel: +8618098282716