Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
KOMEG Technology Ind Co., Limited
Home ProductsThermal Shock Test Chamber

Programmable LCD touch screen Control Thermal Shock Test Chamber for Electronics Testing

China KOMEG Technology Ind Co., Limited certification
China KOMEG Technology Ind Co., Limited certification
Fast delivery and quality products.

—— Gozia

Friendly and pleasant cooperator, "I like the factory, I like the design, I like the workstyle"

—— Wagner

The design and quality impress me a lot.

—— Mr Yee

" A trustworthy supplier of climatic test chamber".

—— Denis

I'm Online Chat Now

Programmable LCD touch screen Control Thermal Shock Test Chamber for Electronics Testing

Programmable LCD touch screen Control Thermal Shock Test Chamber for Electronics Testing
Programmable LCD touch screen Control Thermal Shock Test Chamber for Electronics Testing Programmable LCD touch screen Control Thermal Shock Test Chamber for Electronics Testing Programmable LCD touch screen Control Thermal Shock Test Chamber for Electronics Testing

Large Image :  Programmable LCD touch screen Control Thermal Shock Test Chamber for Electronics Testing

Product Details:
Place of Origin: China
Brand Name: KOMEG
Certification: CE, ISO,
Model Number: KTS-966B
Payment & Shipping Terms:
Minimum Order Quantity: 1SET
Price: negotiation
Packaging Details: Packed in carton firstly, and then reinforced with plywood case for outer packing
Delivery Time: 45 working days after received your payment
Payment Terms: T/T, negotiable
Supply Ability: 1000 SETS / YEAR
Detailed Product Description
Chamber Model: KOMEG Temperature Shock Chamber Chamber Volume Size: 27L To 966L
Shock Range: -55ºC~+150ºC Maximal Temperature: 200°C
Lowest Temperature: -70°C Transition Time: ≤10S
Recovery Time: 5min Lead Time: 60 Workdays
High Light:

temperature shock test chamber

,

thermal shock chamber

 

Programmable LCD touchscreen Control Thermal Shock Chamber for Electronics Testing

 

 

 

1.  Thermal Shock Chambers Overview:

 

Thermal shock test chamber is requisite testing equipment in metal, plastic, rubber, electronics and other industries. It is used for testing the material structure or composite material’s tolerance degree when exposed instantly in extremely high temperature and extremely low temperature environment continuously, so that whose chemical or physical damage due to thermal expansion and contraction can be detected in shortest time.

 

 

 

 

2. KOMEG Thermal Shock Chambers’ Characteristics:

 

1. Heat preservation material, we use high-intensity PU foam and high density glass fiber cotton, which can assure high precise and better uniformity and avoid unnecessary energy loss. Meanwhile, our design can better assure personnel safety when operating a Walk-in Chamber.

 

2. Inner wall and housing material:

For small standard models, generally use inner wall of stainless steel #304 1.0mm, housing of stainless steel #304 1.2mm;

For bigger models, or some customized with special needs, we use inner wall of stainless steel #304 1.5 to 3.0mm, housing of stainless steel #304 over 1.5mm;

 

3. Material quality of inner box is SUS304 # mounted stainless steel imported, and outer box is steel plate and the paint process applies automobile coating technology. Box body is processed shape using Triumph processing machine, its shape is nice and neat.

 

4. Large-size Full Color LCD touchscreen displayer, simple operation, easy to edit programs. PID with automatic calculation function; self-diagnostic function, show failure message and failure shot solutions step by step.

 

5. An RS-232 and RS-485 communication interface, matching recorder, strong expandability. We also support remote control by PC via wifi or wire (recommended).

 

 

 

 

3.  Below are differences between 3-zone and 2-zone thermal shock chamber:

 

3-zone thermal shock chamber:

three chamber in total: test space, high temp. chamber and low temp. chamber;

Advantage: slight limitation for test sample’s weight, the test sample keep still, this can reduce the impact to samples by moving it, can be used for on-load testing.

Compared with 2-zone type, relatively low failure rate, low cost.

Disadvantage: long conversion time

 

2-zone thermal shock chamber:

only two chambers: high temp. Chamber and low temp. chamber

Advantage: short conversion time, smaller space needed

Disadvantage: test sample moving. test samples’ size is limited by the basket size

 

 

 

 

3. Specification

 

(1) KTS-A Series

 

Model

 

KTS-A Series

72A

100A

150A

200A

252A

300A

480A

Inside size(mm)

W

450

500

600

670

700

800

800

H

400

450

500

600

600

600

800

D

400

450

500

500

600

650

750

Outside size(mm)

W

1490

1540

1640

1720

1750

1850

1850

H

1790

1840

1890

2000

2000

2000

2200

D

1600

1700

1830

1850

1930

1980

2500

Test weight

5

10

12

15

18

20

20

Low Temp Chamber

 -55ºC~-10ºC, Pre cooling time: ≤ 60 min from +20ºCto-55ºC

Test Chamber

 -40ºC~+150ºC

High Temp Chamber

 +60ºC~+200ºC ,Within 20 min, Pre-heating time

Transition time

≤15S

Recovery time

High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample

Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample

≤ 5 min

Ambient Temp.

+5ºC~+35ºC

Power

AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires

 

(2) KTS-B Series

 

Model

 

KTS-B Series

72B

100B

150B

200B

252B

300B

480B

Inside size(mm)

W

450

500

600

670

700

800

800

H

400

450

500

600

600

600

800

D

400

450

500

500

600

650

750

Outside size(mm)

W

1490

1540

1640

1720

1750

1850

1850

H

1790

1840

1890

2000

2000

2000

2200

D

1600

1700

1830

1850

1930

1980

2500

Test weight(KG)

5

10

12

15

18

20

20

Low Temp. chamber  

 -70ºC~-10ºC ,Pre cooling time: +20ºC~-70ºC ,≤ 60 min

Test. Chamber  

 -55ºC~+150ºC

High Temp. chamber temperature

 +60ºC~+200ºC,Preheating time: ≤20 min

Transition time

≤15S

Recovery time

High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample

Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample

≤ 5 min

Ambient Temp.

+5ºC~+35ºC

Power

AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires

 

(3) KTS-D Series

 

Model

 

KTS-D Series

72D

100D

150D

200D

252D

300D

480D

Inside size(mm)

W

450

500

600

670

700

800

800

H

400

450

500

600

600

600

800

D

400

450

500

500

600

650

750

Outside size(mm)

W

1490

1540

1640

1720

1750

1850

1850

H

1790

1840

1890

2000

2000

2000

2200

D

1600

1700

1830

1850

1930

1980

2500

Test weight

5

10

12

15

18

20

20

Low Temp Chamber

 -80ºC~-10ºC, Pre cooling time: ≤ 60 min from +20ºCto-80ºC

Test Chamber

 -65ºC~+150ºC

High Temp Chamber

 +60ºC~+200ºC ,Within 20 min, Pre-heating time

Transition time

≤15S

Recovery time

High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample

Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample

≤ 5 min

Ambient Temp.

+5ºC~+35ºC

Power

AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires

 

 

 

 

4. Thermal Shock Chamber Details Picture:

 

Programmable LCD touch screen Control Thermal Shock Test Chamber for Electronics Testing 0

 

 

 

 

 

Contact Details
KOMEG Technology Ind Co., Limited

Contact Person: Anna Hu

Tel: +8618098282716

Send your inquiry directly to us (0 / 3000)