Product Details:
Payment & Shipping Terms:
|
Low Temp Chamber: | -55℃ ~ -10℃ | Humidity Uniformity: | 3.0%RH (no-load) |
---|---|---|---|
Interior Material: | Stainless Steel Plate | Ramping And Soaking Rate: | Heating Up Rate: -20℃↑ +100℃ About 35min (no-load, Ambient Temperature +25℃) Cooling Rate: 20 ℃to -20℃ About 45min (no-load, Ambient Temperature +25℃) |
Humidity Deviation: | ±3.0%RH(>75%RH) ±5.0%RH(≤75%RH) | High Temp Chamber: | +60℃ ~ +200℃ |
Highlight: | 2 Zone Thermal Cycling Chamber,500L Shock Temperature Test Chamber |
Feathers
● GB-2423.1-2008 (IEC68-2-1)Test A: Low Temperature Test
● GB-2423.2-2008(IEC68-2-2)Test B: High Temperature Test
● GJB360.8-2009(MIL-STD.202F) High Temperature Life Test
● GJBl50.3-2009(MIL-STD-810D) High Temperature Test
● GJBl50.4-2009 (MIL-STD-810D) Low Temperature Test
● GB2423.3-2008(IEC68-2-3)Test Ca: Constant Heat Test
● GB2423.4-2008(IEC68-2—30) Test Db: Damp Heat Alternative Test
● GJBl50.9-2009 (MIL-STD-810D) Damp Heat Test
Specification
Capacity(L) |
500L
|
Temperature range |
Low Temp chamber:-55℃ ~ -10℃
High Temp chamber : +60℃ ~ +200℃
|
Temp Deviation |
≦ ± 2.0℃
|
Temp Fluctuation |
±0.5℃
|
Ramping and soaking rate |
Heating up rate: -40℃↑ +100℃ about 45min (no-load, ambient temperature +25℃)
Cooling rate: 20 ℃to -40℃about 60min (no-load, ambient temperature +25℃)
|
Humidity range |
20%R.H~98%R.H
|
Humidity deviation |
±5.0%RH(≤75%RH) |
Humidity uniformity |
3.0%RH (no-load)
|
Humidity fluctuation |
±2.0%RH
|
Basket material(cm) |
71wx34.5HX41Deep
|
Cooling System
Working mode |
Mechanical compression refrigeration
|
Compressor |
Europe and the United States imported hermetic compressor
|
Refrigerant |
Environmental-friendly refrigerant: R404A
|
Condenser |
Shell and Tube condenser(air -cooled)
|
Ambient temp. |
5 ~ 35℃
|
Evaporator |
Fin-type multi-stage automatic load capacity adjustment, No frost in long-term use of
low temperature and humidity conditions |
Other accessories |
Use internationally-known brand, such as high precise expansion valve, oil extractor
dryer and many other accessories. |
Refrigerant flow control |
Adjust energy consumption output and control automatically to the refrigeration system. |
Refrigeration Technology |
Nitrogen welding, two-stage rotary vane vacuum pump, ensure that the internal
cooling system clean and reliable.
water tray located at the bottom of the compressor to ensure condensate water drain
through pipe freely at the rear of the chamber. |
Pre-set function |
Boot time can be set freely and machine runs automatically when turning on
power |
KOMEG brand of Thermal Shock Chamber is the ideal simulation test chamber for all heat and cold testing
between -40 ºC and 180 ºC temperature range. Well-suited for reliability testing based on current test
standards in the temperature range of -40 °C to 150 °C and 10% to 98% RH.Meet all requirements for
extreme testing and low temperature alternating climate profiles from -70 °C - 150 °C with humidity.
For more detail information ,kindly contact : anna@komegtech.com whats app ,wechat :+86-18029096856
Photos show
Contact Person: Ms. KOMEG
Tel: +86-13143135835
Fax: 86-769-83396675