Product Details:
Payment & Shipping Terms:
|
Volume: | 27.1CBM | Temperature Range: | -20 °C To 150 °C |
---|---|---|---|
Material: | SUS304 Stainless Steel | Controller: | LED Touchscreen 7 Inch |
Temperature Constancy: | ±0.5℃ | System: | Balanced Humidity Control System |
High Light: | climatic test chambers,Climatic Testing Chamber |
Ideal temperature and humidity test chamber for Solar and Photovoltaic Industry
Walk-in application
A KOMEG Walk-In Chamber serves as a test site for large components, assemblies, and finished products. KOMEG manufactures both Panel Walk-In Chambers and Solid Walk-In Chambers and can be configured as a temperature chamber or a temperature humidity chamber.
Standard Met and Implemented:
GB/Bb T2423.2-89 high temperature test method
GB2423.1-89 test A: low temperature test method 6
GJB150.4-1986 test at low temperature
IEC60068-2-1 low temperature test method
IEC60068-2-38 temperature cycle
IEC60068-2-78 constant humidity temperature
1. Walk-in Room Construction:
Rooms are constructed of Stainless Steel metal tongue and groove sectional panels. An assembled room has continuous steel perimeters to hold panels tightly in place.
Panel features include:
1) 100% insulation
2) Light weight for easy handling – average weight of the largest panel is 84 lbs.
3) Alignment pins for accurate fit.
4) Steel straps connect locking arms with locking pins on opposite sides of panels.
5) Cam-actuated locks ensure tight fits and accommodate frequent assembly / disassembly for relocating or enlarging the room.
2.Features
Control method and characteristics:
Precision microcomputer control temperature and humidity system, with PID control the refrigerant flow to make the system’s heating / humidification reduction, to achieve low power consumption, energy saving, carbon reduction effect, cooling, heating, humidity control intelligent electronic control, long-term stable use.
3. High temperature limits of test chambers
There are many types of test chambers, but they all high and low temperature limits. Let's take a look at the typical high temperatures thresholds and why they exist.
Test chambers usually have wire heaters made of a material called Nichrome. By placing successive loops of heater wire, a greater amount of heat that is generated. The result looks a lot like the inside of a toaster. Fans circulate the air past the heaters, so the samples in the chamber are not exposed to radiant heat. It is very easy to add heaters and increase the speed and / or high limit of a chamber.
KOMEG chambers typically have a high temperature limits under 200°C. Here is a break-down of why a chamber's high temperature limit exists:
150°C: There are two reasons we may limit a chamber to 150°C. First, there may be a limitation of the materials used inside the chamber. Secondly, for extremely fast chambers, we may limit the high temperature to avoid problems with accidentally tripping overheat protection devices.
170-180°C: Most models stop at this temperature range. There is a risk of burning the oil inside the refrigeration's cooling coil.
4. Specifications
Model | KMHW-4 | |
Volume(m³) | 9CBM | |
Interior Dimensions | W2100 x H2100 x D2050mm | |
Exterior Dimensions | W3250 x H2350 x D2250mm | |
Safety Devices(standard) | No fuse breaker, over pressure, over heat and over current protection for compressor, over temperature protection, over load protection for blower, dry heat protection | |
Standard accessories | Sight window*1, cable port ( portΦ50mm ) *1, chamber lamp*1, status indicator | |
Control System | Balanced Temperature & Humidity Control System | |
Refrigeration system | Water Cooled | |
Semi-hermetic compressor, single stage or cascade refrigeration system, | ||
CFC free refrigerant ( HFC-507 and HFC-23 ) | ||
Controller | Panel | 7-inch LCD Touch panel, Chinese or English display selectable |
Operation model | Program or fix point running | |
Memory capacity | 120 programs,1200steps, all repeat 999 cycles,part repeat 99 cycles | |
Accuracy | Temp.:0.1% of F.S ± 1 digit Humidity:0.1% of F.S ± 1 digit | |
Input | Temp.: pt-100, Humidity: pt-100 or ~5V DCV | |
Comm.port | RS-232 or RS-485 ( Softawre is option) | |
Temp. range | Maximum: 80 ºC,120 ºC; Minimum: -60 ºC, -50 ºC, -40 ºC, -30 ºC, -20 ºC, -10 ºC, 0 ºC | |
Humidity Range | 10%, 20%, 30% ~ 95% | |
Temp. constancy | ±0.5 ºC | |
Humidity constancy | ±2.5%R.H | |
Temp. uniformity | ±2.0 ºC | |
Humidity uniformity | ±5.0%R.H | |
Ambient Temp. | +5 ºC~+35 ºC | |
Wiring method | AC 380 ± 10% 50Hz ,3 phase 4 wires + Ground Wires | |
Heat up time | +20 ºC~+80 ºC, Within 60 min | |
Pull down time | +20 ºC ~ -55 º, -40 ºC, -20 ºC, -10 ºC, Within 120 or 90 or 60 min | |
Interior material | Stainless Steel Plate(SUS 304) | |
Exterior material | Baked Painting Steel Or Stainless steel ( SUS304) | |
Insulation material | Rigid polyurethane foam | |
Door size (mm) | Single wing: W800 x H1800; Double wing: W1600 x H1800; | |
Note: 1. We reserve the right to change specifications without prior notice 2.Customized sizes and configurations available |
5. Temperature and Humidity Test Capabilities
KOMEG have a variety of temperature and humidity chambers from small to walk-in chambers that can reproduce a wide range of climatic conditions incluiding high and low temperature as well as combined temperature and humidity conditions. KOMEG also support a climatic test facility dedicated to tests against requirements for telecoms and radio products.
6.Parts and it's brands
Contact Person: Peter Zhang
Tel: +8615818392160