Product Details:
Payment & Shipping Terms:
|
Material: | Printed Stainless Steel(SUS 304) | Standard: | Internationally Accepted |
---|---|---|---|
Warranty: | 12 Months On Parts (excluding The Damages Caused By The Natural Disasters, Abnormal Power, Improper Operation And Maintenance, Etc) | Payment Terms:: | T/T, L/Cnegotiable |
Warranty: | 1 Year | ||
High Light: | climatic test chambers,Climatic Testing Chamber |
Environmental Test Chamber , Temperature Humidity Chamber For LED Life Evaluation Using
1. Do you know KOMEG?
KOMEG Designed to Meet Internationally Accepted Climatic Test Chambers. As a professional manufacturer and the best brand climatic chamber in China, KOMEG specialized in Environmental testing equipment for quality conscious people since 1990. Our products are CE approved and we are the supplier for ,UL, and world top 500 companies.
Brand : |
KOMEG |
Model : |
Mechanically cooled test chambers, Liquid nitrogen cooled test chambers, Modular Walk-in Chambers |
Application |
To test the effects of specified environmental conditions on industrial products, electronic devices and components, materials, and biological items |
Warranty: |
1 year as standard, longer time can be negotiable |
Place of Origin: |
China |
Custom made |
Available |
2. What we working for ?
Constant Temperature and humidity test chamber is used to test material structure or composite, in the high temperature and ultralow temperature continuous environment.
Toleration of these material to these circumstance. Test chemical change or physical damage caused by their expansion and contraction. Suitable for electronic, LED lighting industry, auto parts, chemical industry, building materials, mobile computers, batteries, plastic, metal, rubber etc. Material.
Under condition of high and low temperature change, test various performance reliability index of related product spare parts and materials for institutions of higher learning, scientific research units etc. Can be used as the basis of improving product or reference.
3 Overview
An environmental test chamber artificially replicates the conditions under which machinery, materials, devices or components might be exposed. It is also used to accelerate the effects of exposure to the environment, sometimes at conditions not actually expected. These conditions may include:
1) Extreme temperatures
2) Sudden and extreme temperature variations
3) Moisture or relative humidity
4) Electrodynamics vibrations
5) Electromagnetic radiation
6) Salt spray
7) Rain
8) Weathering
9) Exposure to sun, causing UV degradation
10) Vacuum
Manufactured samples, specimens, or components are placed inside the chamber and subjected to one or more of these environmental parameters to determine reliability or measure after-effects such as corrosion. In the case of machinery such as internal combustion engines, byproducts such as emissions are monitored.
An environmental chamber can be a small room used both to condition test specimens and to conduct the test. It can be a smaller unit that's used for conditioning test items. Also, some chambers are small enough to be placed onto a universal testing machine or other test apparatus.
Many chambers are set at a certain set of conditions. Others can be programmed to cycle through specified sequences of conditions.
4. Design
As test requirements may be relatively simple or complex, environmental test chambers vary widely in size, ranging from small units designed for placement on bench tops to large walk-in chambers. Test chambers generally have viewports or video feeds to allow for visual inspection of the sample during the test. Reach-in chambers provide an opening that technicians may use to handle test samples. Chambers providing interior visual lighting must take into account the heat generated and compensate accordingly.
As with the wide variance in size, a number of user control options are available, ranging from simple analog indicators up to more modern digital readouts with LCD displays. Chambers may be computer programmable, and networked or Web-enabled test chambers are also available.[1]
5 Types of test chambers
1) Mechanically cooled test chambers
2) Liquid nitrogen cooled test chambers
3) Modular Walk-in Chambers
6 Test chamber standards
Several standards organizations provide standards and guidance on environmental test chamber construction, temperature control standards, and engineering tolerances.
Institute of Environmental Sciences and Technology
Air Conditioning, Heating and Refrigeration Institute (formerly the American Refrigerant Institute)
American Society of Heating, Refrigerating, and Air-Conditioning Engineers Air conditioning American Society of Heating, Refrigerating, and Air-Conditioning Engineers
ASTM International
Underwriters Laboratories
NSF International
Factory Mutual
Canadian Standards Association
International Organization for Standardization
Technical parameters: | |||||
Environmental Temperature and Humidity Chamber | |||||
Secifications ( at +20°C room temp. Or+25°C water temp with empty load) | |||||
Model | KMH-S series | ||||
225S | 408S | 800S | 1000S | ||
Interior sizel | W(mm) | 700 | 700 | 1000 | 1000 |
H(mm) | 700 | 750 | 1000 | 1000 | |
D(mm) | 480 | 800 | 800 | 1000 | |
Exterior size | W(mm) | 980 | 980 | 1280 | 1280 |
H(mm) | 1890 | 1940 | 2160 | 2160 | |
D(mm) | 1460 | 1740 | 1750 | 1950 | |
Weight(KG) | 330 | 450 | 550 | 650 | |
Temp. range | -70 °C ~+150°C | ||||
Humidity Range | 20 ~ 98&R.H. | ||||
Temp. constancy | ±0.5ºC | ||||
Humidity constancy | ±2.5%R.H | ||||
Humidity uniformity | ±3.0%R.H | ±5.0 % R.H | |||
Heat up time | -70°C ~ +100°C , within 60 min | ||||
Pull down time | +20°C ~ -70°C , within 80 min | ||||
Equipment Power | 9.5KW | 10.6KW | 18.5KW | 18.5KW | |
Ambient Temp. | 5ºC ~+35ºC | ||||
Standard accessories | Sight window*1, cable port(port 50mm)*1, shelves*2, chamber lamp*1, power cable *2m | ||||
Safety device (standard) | No fuse breaker, over pressure over heat and over current protection for compressor, | ||||
Over temp. protect, over load protect of blower, dry heat protection | |||||
Control System | Balanced Temperature & Humidity Control System | ||||
Refrigeration system | Air Cooled (Water Cooled Type is option) | ||||
Hermetic compressor,Cascsde Refrigeration | |||||
CFC-Free refrigerant(HFC-507/HFC-23) | |||||
Controller | Panel:7-inch LCD Touch panel, Chinese or English display selectable | ||||
Operation model :Program or fix point running | |||||
Memory capacity :120programs,1200steps, | |||||
All repeat 999 cycles, part repeat 99 cycles | |||||
Interior material | Stainless Steel Plate ( SUS 304 ) | ||||
Exterior material | Baked Painting Steel Or Stainless steel(SUS304) | ||||
Insulation material | Rigid polyurethane Foam and Glass Fiber Wool | ||||
System | Balanced & Humidity Control System | ||||
Wiring method | AC 380±10 % 50Hz ,3 phase 4 wires +Ground Wires | ||||
Note: 1. We reserve the right to change specifications without prior notice 2. Customized sizes and configurations available |
Contact Person: Peter Zhang