Product Details:
Payment & Shipping Terms:
|
Chamber Model: | KTS Series | Chamber Volume Size: | 27L To 480L |
---|---|---|---|
Shock Range: | -65ºC~+150ºC | Maximal Temperature: | 200°C |
Lowest Temperature: | -80°C | Transition Time: | ≤10S |
Recovery Time: | 5min | Lead Time: | 60 Days |
High Light: | temperature shock test chamber,thermal shock chamber |
High and Low Temperature Thermal Shock Chamber for Electronics Performance Testing
1. KOMEG Thermal Shock Chambers’ Characteristics:
1. Heat preservation material, we use high-intensity PU foam and high density glass fiber cotton, which can assure high precise and better uniformity and avoid unnecessary energy loss. Meanwhile, our design can better assure personnel safety when operating a Walk-in Chamber.
2. Inner wall and housing material:
For small standard models, generally use inner wall of stainless steel #304 1.0mm, housing of stainless steel #304 1.2mm;
For bigger models, or some customized with special needs, we use inner wall of stainless steel #304 1.5 to 3.0mm, housing of stainless steel #304 over 1.5mm;
3. Material quality of inner box is SUS304 # mounted stainless steel imported, and outer box is steel plate and the paint process applies automobile coating technology. Box body is processed shape using Triumph processing machine, its shape is nice and neat.
4. Large-size Full Color LCD touchscreen displayer, simple operation, easy to edit programs. PID with automatic calculation function; self-diagnostic function, show failure message and failure shot solutions step by step.
5. An RS-232 and RS-485 communication interface, matching recorder, strong expandability. We also support remote control by PC via wifi or wire (recommended).
2. Below are differences between 3-zone and 2-zone thermal shock chamber:
3-zone thermal shock chamber:
three chamber in total: test space, high temp. chamber and low temp. chamber;
Advantage: slight limitation for test sample’s weight, the test sample keep still, this can reduce the impact to samples by moving it, can be used for on-load testing.
Compared with 2-zone type, relatively low failure rate, low cost.
Disadvantage: long conversion time
2-zone thermal shock chamber:
only two chambers: high temp. Chamber and low temp. chamber
Advantage: short conversion time, smaller space needed
Disadvantage: test sample moving. test samples’ size is limited by the basket size
3. Specification
(1) KTS-A Series
Model |
|
||||||||
72A |
100A |
150A |
200A |
252A |
300A |
480A |
|||
Inside size(mm) |
W |
450 |
500 |
600 |
670 |
700 |
800 |
800 |
|
H |
400 |
450 |
500 |
600 |
600 |
600 |
800 |
||
D |
400 |
450 |
500 |
500 |
600 |
650 |
750 |
||
Outside size(mm) |
W |
1490 |
1540 |
1640 |
1720 |
1750 |
1850 |
1850 |
|
H |
1790 |
1840 |
1890 |
2000 |
2000 |
2000 |
2200 |
||
D |
1600 |
1700 |
1830 |
1850 |
1930 |
1980 |
2500 |
||
Test weight |
5 |
10 |
12 |
15 |
18 |
20 |
20 |
||
Low Temp Chamber |
-55ºC~-10ºC, Pre cooling time: ≤ 60 min from +20ºCto-55ºC |
||||||||
Test Chamber |
-40ºC~+150ºC |
||||||||
High Temp Chamber |
+60ºC~+200ºC ,Within 20 min, Pre-heating time |
||||||||
Transition time |
≤15S |
||||||||
Recovery time |
High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample |
||||||||
Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample |
|||||||||
≤ 5 min |
|||||||||
Ambient Temp. |
+5ºC~+35ºC |
||||||||
Power |
AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires |
(2) KTS-B Series
Model |
|
||||||||
72B |
100B |
150B |
200B |
252B |
300B |
480B |
|||
Inside size(mm) |
W |
450 |
500 |
600 |
670 |
700 |
800 |
800 |
|
H |
400 |
450 |
500 |
600 |
600 |
600 |
800 |
||
D |
400 |
450 |
500 |
500 |
600 |
650 |
750 |
||
Outside size(mm) |
W |
1490 |
1540 |
1640 |
1720 |
1750 |
1850 |
1850 |
|
H |
1790 |
1840 |
1890 |
2000 |
2000 |
2000 |
2200 |
||
D |
1600 |
1700 |
1830 |
1850 |
1930 |
1980 |
2500 |
||
Test weight(KG) |
5 |
10 |
12 |
15 |
18 |
20 |
20 |
||
Low Temp. chamber |
-70ºC~-10ºC ,Pre cooling time: +20ºC~-70ºC ,≤ 60 min |
||||||||
Test. Chamber |
-55ºC~+150ºC |
||||||||
High Temp. chamber temperature |
+60ºC~+200ºC,Preheating time: ≤20 min |
||||||||
Transition time |
≤15S |
||||||||
Recovery time |
High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample |
||||||||
Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample |
|||||||||
≤ 5 min |
|||||||||
Ambient Temp. |
+5ºC~+35ºC |
||||||||
Power |
AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires |
(3) KTS-D Series
Model |
|
||||||||
72D |
100D |
150D |
200D |
252D |
300D |
480D |
|||
Inside size(mm) |
W |
450 |
500 |
600 |
670 |
700 |
800 |
800 |
|
H |
400 |
450 |
500 |
600 |
600 |
600 |
800 |
||
D |
400 |
450 |
500 |
500 |
600 |
650 |
750 |
||
Outside size(mm) |
W |
1490 |
1540 |
1640 |
1720 |
1750 |
1850 |
1850 |
|
H |
1790 |
1840 |
1890 |
2000 |
2000 |
2000 |
2200 |
||
D |
1600 |
1700 |
1830 |
1850 |
1930 |
1980 |
2500 |
||
Test weight |
5 |
10 |
12 |
15 |
18 |
20 |
20 |
||
Low Temp Chamber |
-80ºC~-10ºC, Pre cooling time: ≤ 60 min from +20ºCto-80ºC |
||||||||
Test Chamber |
-65ºC~+150ºC |
||||||||
High Temp Chamber |
+60ºC~+200ºC ,Within 20 min, Pre-heating time |
||||||||
Transition time |
≤15S |
||||||||
Recovery time |
High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample |
||||||||
Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample |
|||||||||
≤ 5 min |
|||||||||
Ambient Temp. |
+5ºC~+35ºC |
||||||||
Power |
AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires |
4. Product Details Picture:
Contact Person: Anna Hu
Tel: +8618098282716