Product Details:
Payment & Shipping Terms:
|
Chamber Model: | KTS Series | Chamber Volume Size: | 27L To 480L |
---|---|---|---|
Shock Range: | -65ºC~+150ºC | Maximal Temperature: | 200°C |
Lowest Temperature: | -80°C | Transition Time: | ≤10S |
Recovery Time: | Less Than 5min | Exposure Time: | Within 30 Mins |
High Light: | Stainless Steel Battery Test Chamber,27L Thermal Shock Test Chamber,480L Thermal Shock Test Chamber |
Asia Popular Type Stainless Steel 3-Zone Thermal Shock Test Chamber for Battery Testing
1. Thermal Shock Test Chamber :
Thermal shock test chamber is requisite testing equipment in metal, plastic, rubber, electronics and other industries. It is used for testing the material structure or composite material’s tolerance degree when exposed instantly in extremely high temperature and extremely low temperature environment continuously, so that whose chemical or physical damage due to thermal expansion and contraction can be detected in shortest time.
2. 3-Zone Thermal Shock Chambers Working Principle:
The three-zone type thermal shock test chamber. Sample is placed in the test chamber, more extreme temperature than test temperature can be set in high-temperature chamber and low-temperature chamber. During low temperature test, cold chamber door open, and low-temperature chamber working together with test chamber. When converted into high-temperature test, cold chamber door closed, hot chamber door are opened, and test chamber working together with high-temperature chamber.
Conversion of mechanical action (transferring from high temperature to low temperature or low temperature to high temperature) can be completed in less than 1 second, and the temperature can be quickly stabilized.
During the whole test, test sample is no need to be moved, and without any human intervention.
3. Specification
(1) KTS-A Series
Model |
|
||||||||
72A |
100A |
150A |
200A |
252A |
300A |
480A |
|||
Inside size(mm) |
W |
450 |
500 |
600 |
670 |
700 |
800 |
800 |
|
H |
400 |
450 |
500 |
600 |
600 |
600 |
800 |
||
D |
400 |
450 |
500 |
500 |
600 |
650 |
750 |
||
Outside size(mm) |
W |
1490 |
1540 |
1640 |
1720 |
1750 |
1850 |
1850 |
|
H |
1790 |
1840 |
1890 |
2000 |
2000 |
2000 |
2200 |
||
D |
1600 |
1700 |
1830 |
1850 |
1930 |
1980 |
2500 |
||
Test weight |
5 |
10 |
12 |
15 |
18 |
20 |
20 |
||
Low Temp Chamber |
-55ºC~-10ºC, Pre cooling time: ≤ 60 min from +20ºCto-55ºC |
||||||||
Test Chamber |
-40ºC~+150ºC |
||||||||
High Temp Chamber |
+60ºC~+200ºC ,Within 20 min, Pre-heating time |
||||||||
Transition time |
≤15S |
||||||||
Recovery time |
High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample |
||||||||
Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample |
|||||||||
≤ 5 min |
|||||||||
Ambient Temp. |
+5ºC~+35ºC |
||||||||
Power |
AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires |
(2) KTS-B Series
Model |
|
||||||||
72B |
100B |
150B |
200B |
252B |
300B |
480B |
|||
Inside size(mm) |
W |
450 |
500 |
600 |
670 |
700 |
800 |
800 |
|
H |
400 |
450 |
500 |
600 |
600 |
600 |
800 |
||
D |
400 |
450 |
500 |
500 |
600 |
650 |
750 |
||
Outside size(mm) |
W |
1490 |
1540 |
1640 |
1720 |
1750 |
1850 |
1850 |
|
H |
1790 |
1840 |
1890 |
2000 |
2000 |
2000 |
2200 |
||
D |
1600 |
1700 |
1830 |
1850 |
1930 |
1980 |
2500 |
||
Test weight(KG) |
5 |
10 |
12 |
15 |
18 |
20 |
20 |
||
Low Temp. chamber |
-70ºC~-10ºC ,Pre cooling time: +20ºC~-70ºC ,≤ 60 min |
||||||||
Test. Chamber |
-55ºC~+150ºC |
||||||||
High Temp. chamber temperature |
+60ºC~+200ºC,Preheating time: ≤20 min |
||||||||
Transition time |
≤15S |
||||||||
Recovery time |
High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample |
||||||||
Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample |
|||||||||
≤ 5 min |
|||||||||
Ambient Temp. |
+5ºC~+35ºC |
||||||||
Power |
AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires |
(3) KTS-D Series
Model |
|
||||||||
72D |
100D |
150D |
200D |
252D |
300D |
480D |
|||
Inside size(mm) |
W |
450 |
500 |
600 |
670 |
700 |
800 |
800 |
|
H |
400 |
450 |
500 |
600 |
600 |
600 |
800 |
||
D |
400 |
450 |
500 |
500 |
600 |
650 |
750 |
||
Outside size(mm) |
W |
1490 |
1540 |
1640 |
1720 |
1750 |
1850 |
1850 |
|
H |
1790 |
1840 |
1890 |
2000 |
2000 |
2000 |
2200 |
||
D |
1600 |
1700 |
1830 |
1850 |
1930 |
1980 |
2500 |
||
Test weight |
5 |
10 |
12 |
15 |
18 |
20 |
20 |
||
Low Temp Chamber |
-80ºC~-10ºC, Pre cooling time: ≤ 60 min from +20ºCto-80ºC |
||||||||
Test Chamber |
-65ºC~+150ºC |
||||||||
High Temp Chamber |
+60ºC~+200ºC ,Within 20 min, Pre-heating time |
||||||||
Transition time |
≤15S |
||||||||
Recovery time |
High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample |
||||||||
Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample |
|||||||||
≤ 5 min |
|||||||||
Ambient Temp. |
+5ºC~+35ºC |
||||||||
Power |
AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires |
4. Product Details Picture:
5. Below are differences between 3-zone and 2-zone thermal shock chamber:
3-zone thermal shock chamber:
three chamber in total: test space, high temp. chamber and low temp. chamber;
Advantage: slight limitation for test sample’s weight, the test sample keep still, this can reduce the impact to samples by moving it, can be used for on-load testing.
Compared with 2-zone type, relatively low failure rate, low cost.
Disadvantage: long conversion time
2-zone thermal shock chamber:
only two chambers: high temp. Chamber and low temp. chamber
Advantage: short conversion time, smaller space needed
Disadvantage: test sample moving. test samples’ size is limited by the basket size
Contact Person: Anna Hu
Tel: +8618098282716