Product Details:
Payment & Shipping Terms:
|
High Temp Chamber: | -70℃ ~+180℃ | Ambient Temp: | +5℃ ~+35℃ |
---|---|---|---|
Interior Material: | SUS 304 | Exterior Material: | Baked Painting Steel |
Compressor: | Semi-Hermetic Compressor | Cooling Mode: | Water Cooled |
Highlight: | Environmental Stress Screening Chambers,Thermal Shock Test Chamber |
OEM and ODM are welcome ,pls kindly contact:anna@komegtech.com
Temperature adaptability test under the condition of rapid change, or gradient for electrical, electronic
,
instruments and other products or spareparts, particularly applies to environmental stress screening
test(ESS)
The high-precision microcomputer controlled temperature control system is controlled by PID method to
reduce the heating of the system to achieve low energy consumption, energy saving and carbon reduction
effect. The electronic control of heating electronic control can be used stably for a long time.
Features
Rational Construction and fast cooling rate
Frequency conversion control of wind speed.
Adopts international brand of imported parts for cooling system to improve operation reliability
Touch screen controller, friendly Man-Machine interface and safety device to ensure simple operation and easy maintenance
Specification
Model | ESS- | |||||||||
Nonlinear | linear | |||||||||
Working Chamber Volume (litter | 150L-C5 | 225L-C5 | 408L-C5 | 800L-C5 | 1000L-C5 | 150L-C5 | 225L-C5 | 408L-C5 | 800L-C5 | 1000L-C5 |
Interior size (WXH XD cm) | 60 | 70 | 70 | 100 | 100 | 60 | 70 | 70 | 100 | 100 |
60 | 70 | 75 | 100 | 100 | 60 | 70 | 75 | 100 | 100 | |
46 | 48 | 80 | 80 | 100 | 46 | 48 | 80 | 80 | 100 |
Ⅳ.Main Technical Parameters
|
|
1. Chamber (Water cooled)
|
|
1.1 Workspace volume |
W 1000 × H 1000 × D 800 mm
|
1.2 Exterior size |
W 1200 × H 2030 × D 2645 mm
|
2. Temperature
|
|
2.1 Temperature range |
-70℃~+180℃
|
2.2 Temp Deviation |
≤±1.0°C(≤±0.5°C, according to GB/T5170-1996)
|
2.3 Temp Constancy |
±0.5°C
|
2.4 Temp Uniformity |
≤±2.0°C
|
2.5Temperature change rate: |
(according to IEC 60068-3-5 standard)
From -70 °C to +180°C take -45°C ~ +155°C to observe the rate of the entire temperature rise process should meet the requirements
|
Humidity
|
|
Humidity control range |
20%R.H~98%R.H
|
More information ,pls kindly contact us :anna@komegtech.com
Photos show
Contact Person: Ms. KOMEG
Tel: +86-13143135835
Fax: 86-769-83396675