Product Details:
Payment & Shipping Terms:
|
Interior Dimension: | W 1200 × D 800 × H 500 Mm | External Dimension: | W 1700 × D 950 × H 1210 Mm |
---|---|---|---|
Power: | 220V / 50HZ. 15KW | Test Room: | 35℃±1℃ |
Air Pressure Barrels:47℃±1℃: | 47℃±1℃ | Corrosion Resistance Test:: | CASS |
Ⅰ. Application
|
|||
Salt spray test machine is specifically designed for materials surface corrosion resistance testing, these
materials are treated in kinds of paint, coating, plating, antirust oil treated, etc.; widely used in metal,
electro, electronic, chemical, automotive, aviation, aerospace, telecommunications and other industries.
Carrying out corrosion testing for the products of materials and coating, so as to analyze and evaluate
the samples’ performance under specific environmental conditions of marine environment. |
|||
Ⅱ. Main Specifications
|
|||
|
|||
1.Interior dimension |
W 1200 × D 800 × H 500 mm
|
||
1.2External dimension |
W 1700 × D 950 × H 1210 mm
|
||
2.Power Supply
|
|||
2.1 Power |
220V / 50HZ. 15KW
|
||
Ⅲ. Feature
|
|||
3.1 Box material |
The inside and outside the box are made of high temperature and high humidity
corrosive high grade A gray PVC (thickness 8 ~ mm), the use of advanced
production technology with three-dimensional ring, welded, solid structure, never
deformation, gorgeous, applicable to salt spray, copper acetate and other testing
specifications. |
||
3.2 Reagent bottle |
Conceal one-piece reagent bottle, easy cleanout and operation.
|
||
3.3Air pressure barrel |
It is made of SUS304 # stainless steel, refined tank structure design, high
temperature, high humidity, high pressure, high corrosiveness resistant., and
after several years of accumulated experience, successfully solved the short
time water shortage of the general salt spray machine technical problems,
unique internal design of the pressure tank, so that water shortage in pressure
tank is no longer your worry and troubles. It is in a leading position in the industry.
|
||
3.4Test sample holder |
A "gray" PVC material is refined into a "V" shaped strip. The full set is made of
molds. The strength is higher. It is matched with tempered glass straight 10mm
"O" strip to ensure that the product 15 ° -30 ° angle of the test sample rack using
flat indexing, can adjust the angle, four fog uniform, consistent by the fog, the
test results are accurate, the number of test samples placed more. |
||
3.5 Chamber cover |
Using a 5mm thick transparent PVC plate with high toughness, a 100 degree
ridge transparent cover was designed by physical bending method, so that dew
droplets remaining on the cover slid along the cover wall to the sealing groove
not fall the test products. |
||
3.6 Other Function |
A. With self-detection and other advanced features, is a great choice for your multiplier.
B. All-digital circuit design, accurate temperature control, use high-quality
imported electrical materials, reasonable wiring design, long life, test function is complete.
C. With power outage memory function, so that the original time after the call to
complete the remaining time to complete the test Inspection work, with double
over-temperature protection, water level warning, to ensure safe use.
D. Spray and stop fog time can be set separately for circulating intermittent spray.
E. Fog seal tank using environmentally friendly water sealing, to prevent mist leakage.
F. Spray tower with conical disperser, with a guided fog, adjust the fog and even falling fog, etc.
G. The instrument adopts ergonomic design, beautiful appearance, easy operation. |
||
IV.Technical base.
|
|||
According to the standard parameter of JIS, ASTM, CNS, GB.
|
|||
salt spray test: NSS, ACSS
test room:35℃±1℃
Air pressure barrels:47℃±1℃
② Corrosion resistance test: CASS
test room:50℃±1℃
Air pressure barrels: 63℃±1℃ |
|||
4.1 Air supply system |
Air pressure is two-stage adjustment, the first is roughly adjustment 2 Kg/cm2,
import air filter with the function of water draining, the second is accurate
adjustment 1Kg/cm2,1/4 pressure gage, show precision and accuracy. |
||
4.2 Mist spray pattern
|
Knut principle absorb the salt water and then atomization, fogging degree is on
average, no block and crystal phenomenon absolutely, make sure the test
proceed continuously.
|
||
4.3 Heating system | Adopt direct heating way, fast rate of temperature increase so reduce the standby time, when reach the temperature, automatic shift temperature constant state, accuracy temperature, low power consumption. Pure titanium heating tube, resistance to acid and alkali corrosion, overlength working life. | ||
4.4 Control system: |
Control Panel
|
||
4. 5 Safety Protection | Laboratory pressure saturation tank heating tank with liquid expansion safety temperature controller 0 ~ 120 ℃ (Italy EGO). Automatic, manual two water systems, automatic or manual pressure bucket, laboratory water level, to prevent water damage to ultra-high temperature instruments. | ||
4.6 Safety protection device:
|
|
||
4.7 Working principle | Knut principle draws brine and atomizes it. The degree of atomization is uniform without clogging the crystals. This ensures that the test is continuously carried out and the compressed air is moistened by the bubble column leading to the nozzle. The nozzle will corrode the solution and air Atomized into a corrosive gas mist, the heater inside the box to keep the temperature inside. | ||
4.8Standard installation | 1:V type/O type Support 1 set | ||
2: Hopper 2 pcs | |||
3: Collector 2 pcs | |||
4: Glass nozzles 1 pcs | |||
5: Automatic Defog function 1 set | |||
6: Spray tower 1 set | |||
7: Reagent sodium chloride(500g/bottle) 2bottle | |||
8: Operating manual 1 set | |||
9: Plastic rust-proof barrels(5Lcapacity) 1 set | |||
10: Automatic filling water 1 set | |||
4.9Ambient environment |
1. Power Supply:220V / 50HZ. 15KW 2.Operating ambient temperature:5~30℃ 3. Using water quality: (1).Neutral test fluid mixing——distilled water(pure water)(The HP value should be 6.5 ~ 7.2) (2). Acid test solution deployment - distilled water (pure water) (the HP value should be between 3.0 to 3.3) (3) The rest of the water - tap water 4.Air pressure setting (1).Spray pressure——1.0±0.1kgf/cm2 (2). Air compressor surge tank filter——2.0~2.5kgf/ cm 5.Installed at the edge of the window, be helpful for the exhaust, drainage |
||
4.10Easily damaged parts | Salt spray nozzle, meter measuring cylinder | ||
4.11Consumables | Sodium chloride, purified water and tap water |
Photos show
Contact Person: Ms. KOMEG
Tel: +86-13143135835
Fax: 86-769-83396675