Product Details:
Payment & Shipping Terms:
|
Interior Dimensions: | 160*50*100cm | Temp. Range: | 35~50°C |
---|---|---|---|
Saturated Air Barrel Temperature: | 47±1°C For Salt Spray Method (NSS ACSS), 63±1°C For Corrosion-resistant Testing Method(CASS) | PH: | 6.5~7.2 For Salt Spray Method (NSS ACSS)and 3.0~3.2 For Corrosion-resistant Testing Method(CASS) |
Heater: | 15KW+1KW | Air Compressor: | 2HP |
High Light: | salt spray testing machine,salt spray test equipment |
Environmental Salt Spray Test Chamber Equipment 60L For Industrial
Brand |
KOMEG |
Model |
HL-60-SS |
Design standards: |
IEC68-2-11,JIS,H8502,ASTM B-117-97,ISO9227,CNS3627,3885, 4159,7669,8886,JIS D-0201 |
Application |
Corrosion-resistant Test for surface treatment such as coating, electroplating, films of organic and non-organic materials, anodizing, anti-rest oil and corrosion resistant treatment, |
Warranty: |
12 month on parts (excluding the damages caused by the natural disasters, abnormal power, improper operation and maintenance, etc) |
Place of Origin: |
China |
Custom made |
Available |
A. The whole part of the device is made of P.V.C. Sheet and the inside of the device is reinforced by using a special lining material. Thus, it is sturdily made and will not transform forever.
B. In order to ensure the temperature difference in the machine can be kept within (± 1℃), the test machine is heated from five directions.
C. Spray nozzle: The nozzle is specially made to enable it to suck up the salt water and then spray it out in the shape of mist with considerable high speed. When it falls on the surface of the item being tested, the difference of fallen mist may be controlled within ± 0.3ml / 80 cm2h.
D. Heater principle: make the saturated air hot and moist then keep the humidity in the test chamber required for test.
E. Temperature is the pre-requisite condition that have direct impact on corrosion rate. To limit the temperature difference within the range of ± 0.5℃, we use P.I.D. temperature control unit.
F. A warning device is used to indicate the low level of the test fluid, when the fluid is only enough for being sprayed for five hours, a buzzer will remind the user to replenish the liquid to ensure continuous spray test.
G. Use full automatic detecting system, test stopped automatic, and lighting display when trouble.
Model |
HL-160-NS |
HL-90-BS |
HL-60-SS |
Inside box size (W*H*D) |
1600*500*1000 mm |
900*500*600 mm |
600*400*450 mm |
Out side box size(W*H*D) |
2240*1500*1600 mm |
1460*1280*910 mm |
1130*1070*630 mm |
Working Volume(L) |
800 |
270 |
60 |
Heater |
15KW+1KW |
7KW+0.75KW |
3KW+0.75KW |
Air compressor |
2HP |
1/2HP |
1/2HP |
Test Chamber Temp |
35±1°C for Salt Spray Method (NSS ACSS) 50±1°C for Corrosion-resistant Testing Method(CASS) |
||
Saturated air Barrel Temperature |
47±1°C for Salt Spray Method (NSS ACSS) |
||
PH |
6.5~7.2 for Salt Spray Method (NSS ACSS) 3.0~3.2 for Corrosion-resistant Testing Method(CASS) |
||
Multiple Safety Protection Devices : |
Current discharge protection, over pressure protection,over temperature protection, over load fuse protection |
||
Power |
AC220V 1Φ 50Hz |
1. Salt Spray Test Chamber System Diagram
2. Combined Cycle Tester System Diagram
3. Salt Spray Testing working Principle
Contact Person: Peter Zhang
Tel: +8615818392160