Product Details:
Payment & Shipping Terms:
|
Blanket Dimension: | W 380 × H 370 × D 430 Mm | Overall Dimension: | W 1330 × H 2260 × D 2300 Mm |
---|---|---|---|
High Temperature Range: | +50℃~+250℃ | Temperature Increasing Time: | +50℃~+250℃ ≧ 17℃/min |
Inner Housing: | SUS304# Stainless Steel | Insulation Materials: | Rigid Polyurethane Foam Insulation Layer + Glass Fiber |
High Light: | thermal shock chamber,environmental testing chambers |
High temperature cabinet: W 380 × H 370 × D 430 mm 64L 2-Zone Thermal Shock Test Equipment
Applications
2-zone Thermal shock chamber have been designed to operate in accordance with reliability programs,
quality control, commercial test programs and medical tests. It is used to test the capability of material
structure or composite material to withstand the continuous environmental changes between extremely
high temperature and low temperature during a short period. It is applicable to metals, plastic, rubber,
electronics amongst other materials. The test result can be used as a reference or basis for produce
improvement.
Specifications
Test cabinet basket Volume | 60L |
Test cabinet basket dimension | W 380 × H 370 × D 430 mm |
Test Cabinet External husing dimension | W 1330 × H 2260 × D 2300 mm(Excluding the prominent part of the chamber) |
Operating parameters | |
Environment condition | Air Cooling and the temperature is +25C, no loading |
High Temperature Cabinet: |
+50℃~+250℃ |
Heating time |
+50℃~+250℃ ≧ 17℃/min Note: the heating time is the performance of the high temperature chamber running separately, according to IEC 60068-3-5 measurement. |
Low Temperature Cabinet: |
-80℃~+70℃ |
Low temperature rise time |
-80℃~+70℃ ≧ 3.0℃/min Note: the heating time is the performance of the high temperature chamber running separately, according to IEC 60068-3-5 measurement. |
Low greenhouse Cooling time |
+70℃~-80℃ ≧ 3.5℃/min Note: the cooling time is the performance of the cryogenic chamber running independently, according to IEC 60068-3-5 measurement. |
Transfer time | Less than 15 seconds |
Temperature fluctuation | ±0.5℃ |
Temperature deviation | ±2.0℃ |
Temperature unifomity | ±2.0℃ |
Single room control | High and low greenhouses can be individually controlled |
Other | The temperature change rate and basket start position can be set before and after the cycle |
Structure | |
Insulation box |
wall material: high-quality carbon steel with static color spray inner wall material: SUS304 # matte stainless steel plate Insulation materials: rigid polyurethane foam insulation layer + glass fiber. |
Air conditioning channel | Fans, heaters, evaporators, temperature sensors. |
Standard configuration of test box |
Lead hole: 1, 1 holes 50mm on the top of the box. Sample shelf: 2; Sample basket: 1, each bearing capacity (uniform): 20kg. |
Adjust feet and adjust wheel |
Adjust feet: 4, support the test box; Adjust wheel: 4, mobile test box. |
Door | Single door, left hinge, right handle (manual lock door), with windows W210*H270mm. |
Circulating fan, low temperature exposure, high temperature preheating |
3 1HP, centrifugal type; 3 1HP, centrifugal type. |
Control panel | Controller display, fault indicator, USB interface, main power switch, RS-485 communication interface. |
Machinery room | Refrigeration unit, water drainage device, exhaust fan. |
Distribution control cabinet | Main power leakage circuit breaker, controller, distribution board, cooling fan, high and low temperature circulating air motor. |
Heater |
Nickel-chromium alloy heating wire heater; Heater control mode: no contact and other periodic pulse width adjustment, SSR (solid state relay). |
Standards Met and Implemented:
GB/T2423.1.2
GB10592-89
GJB150
Prouduct Display
Packing and Shipment:
Contact Person: Anna Hu
Tel: +8618098282716