Product Details:
Payment & Shipping Terms:
|
Product Name: | Programmable Walk-in Test Chambers | Application: | Reliability Testing, Research & Development Testing, Failure Analysis |
---|---|---|---|
Volume(M3): | 16.8CBM | Temp. Constancy: | +/-0.5oc |
Humidity Constancy: | +/-2.5%R.H | H.S. Code: | 90321000 |
Delivery: | 42 Working Days | Installation: | Yes Based On Your Arrangement Of Room And Board |
High Light: | walk in humidity chamber,walk in climatic chamber |
BTC System 16.8 Cubic Constant Temperature Environmental Walk-in Room
1. Walk-In Temperature and Climate Test Chambers
1.1 The KMHW series of walk-in temperature and climate test chambers are especially developed for large test specimens. Size and design mean optimal loading of test specimens. The modular construction and variability in size and equipment is ideally for costumerspecific application.
1.2 Walk in chambers can be used for testing and controlled storage as well as a multifunctional laboratory environment for conducting test procedures in the telecommunications, defense, aerospace, pharmaceutical, automotive, and electronics industries. Chamber sizes can always be customized to your testing needs.
2. Main Technical Parameters
Model | KMHW-8 | |||||||
Volume(m³) | 16.8CBM | |||||||
Interior Dimensions | W3900 x H2100 x D2050mm | |||||||
Exterior Dimensions | W5050 x H2350 x D2250mm | |||||||
Safety Devices(standard) | No fuse breaker, over pressure, over heat and over current protection for compressor, over temperature protection, over load protection for blower, dry heat protection | |||||||
Standard accessories | Sight window*1, cable port ( portΦ50mm ) *1, chamber lamp*1, status indicator | |||||||
Control System | Balanced Temperature & Humidity Control System | |||||||
Refrigeration system | Water Cooled | |||||||
Semi-hermetic compressor, single stage or cascade refrigeration system, | ||||||||
CFC free refrigerant ( HFC-507 and HFC-23 ) | ||||||||
Controller | Panel | 7-inch LCD Touch panel, Chinese or English display selectable | ||||||
Operation model | Program or fix point running | |||||||
Memory capacity | 120 programs,1200steps, all repeat 999 cycles,part repeat 99 cycles | |||||||
Accuracy | Temp.:0.1% of F.S ± 1 digit Humidity:0.1% of F.S ± 1 digit | |||||||
Input | Temp.: pt-100, Humidity: pt-100 or ~5V DCV | |||||||
Comm.port | RS-232 or RS-485 ( Softawre is option) | |||||||
Temp. range | Maximum: 80 ºC,120 ºC; Minimum: -60 ºC, -50 ºC, -40 ºC, -30 ºC, -20 ºC, -10 ºC, 0 ºC |
|||||||
Humidity Range | 10%, 20%, 30% ~ 95% | |||||||
Temp. constancy | ±0.5 ºC | |||||||
Humidity constancy | ±2.5%R.H | |||||||
Temp. uniformity | ±2.0 ºC | |||||||
Humidity uniformity | ±5.0%R.H | |||||||
Ambient Temp. | +5 ºC~+35 ºC | |||||||
Wiring method | AC 380 ± 10% 50Hz ,3 phase 4 wires + Ground Wires | |||||||
Heat up time | +20 ºC~+80 ºC, Within 60 min | |||||||
Pull down time | +20 ºC ~ -55 º, -40 ºC, -20 ºC, -10 ºC, Within 120 or 90 or 60 min | |||||||
Interior material | Stainless Steel Plate(SUS 304) | |||||||
Exterior material | Baked Painting Steel Or Stainless steel ( SUS304) | |||||||
Insulation material | Rigid polyurethane foam | |||||||
Door size (mm) | Single wing: W800 x H1800; Double wing: W1600 x H1800; | |||||||
Note:1. We reserve the right to change specifications without prior notice 2.Customized sizes and configurations available |
3. Feactures:
a. Touch panel for the convenient input of fixed values and programming with graphic depiction of nominal and real values, operating time, remaining cycles etc., including help functions
b. Programme memory for up to 100 programmes with a total of 1000 sections
c. Software support for potential-free inputs and outputs
d. Password protection, two-stage, to avoid unintentional alteration
e. Integrated limit value monitoring system for temperature and humidity
f. Inspection system provides information on malfunctions and collects operating time dat
4. Standard Version
5. Walk-in Room Internal Show
Contact Person: Peter Zhang
Tel: +8615818392160