Product Details:
Payment & Shipping Terms:
|
Product Name: | Walk-in Test Chamber | Application: | Vehicle Testing, Automotive Components, Solar Panels, Electronic Components |
---|---|---|---|
Volume(M3): | 35CBM | Door Size: | Double Open Door With Big Windows |
Temp. Constancy: | +/-0.5oc | Humidity Constancy: | +/-2.5%R.H |
H.S. Code: | 90321000 | Delivery: | 60 Working Days |
Installation: | Yes | Warranty Period: | 1 To 5 Years Optional |
High Light: | walk in environmental chamber,walk in humidity chamber |
Economical Price Environmental Walk-In Chamber for vehicle automotive components cable wires Testing
Environmental Walk-In Test Chambers APPLICATION:
KOMEG offers a broad selection of various types of walk-in chambers to meet almost any test requirement.
Heat pump testing chambers belong to the modular chambers test equipment family. They are meant for characterization of heat pumps and associated equipments. We offer you a comprehensive serie of tests for every firms that produce and sell heat pump.
These chambers enable :
the characterization of thermodynamic materials linked to renewable energies.
to control performance of heat pump according to outside conditions within a wide range of temperature and humidity. These controls are carried out according to manufacturers requirements.
Offers flexibility for testing larger volumes at an economical price
Modular Walk-In chambers offer flexibility to meet virtually any size or configuration by using pre-fabricated / insulation panels.
Modular chambers are constructed of 4” /100mm thick polyurethane-foamed panels that lock together to form a tightly sealed
chamber with stainless steel interior and aluminum or white embossed exterior. Available in a variety of temperature
ranges to meet your specific testing needs
Modular Climate Conditioning Systems
Type:
temperature, humidity
Options and accessories:
modular
Temperature range for modular type walk-in chamber:
Min.: -50 °C
Max.: +85 °C
Heat preservation material, we use high-intensity PU foam high density glass fiber cotton,
which can assure high precise and better uniformity and avoid unnecessary energy loss.
Large glass window design, viewing angle in all directions,
hollow electric plating film and anti-condensation design;
built-in LED lights to facilitate the test sample state of real-time observation in the course of testing;
double door design, the inner big glass door with hand-in holes for the convenient operating.
Walk-In Test Chambers Main Technical Parameters
Model | KMHW-120 | |||||||
Volume(m³) | 35.2CBM | |||||||
Interior Dimensions | W4000 x H5000 x D6000mm | |||||||
Exterior Dimensions | Actually design | |||||||
Safety Devices(standard) | No fuse breaker, over pressure, over heat and over current protection for compressor, over temperature protection, over load protection for blower, dry heat protection | |||||||
Standard accessories | Sight window*1, cable port ( portΦ50mm ) *1, chamber lamp*1, status indicator | |||||||
Control System | Balanced Temperature & Humidity Control System | |||||||
Refrigeration system | Water Cooled | |||||||
Semi-hermetic compressor, single stage or cascade refrigeration system, | ||||||||
CFC free refrigerant ( HFC-507 and HFC-23 ) | ||||||||
Controller | Panel | 7-inch LCD Touch panel, Chinese or English display selectable | ||||||
Operation model | Program or fix point running | |||||||
Memory capacity | 120 programs,1200steps, all repeat 999 cycles,part repeat 99 cycles | |||||||
Accuracy | Temp.:0.1% of F.S ± 1 digit Humidity:0.1% of F.S ± 1 digit | |||||||
Input | Temp.: pt-100, Humidity: pt-100 or ~5V DCV | |||||||
Comm.port | RS-232 or RS-485 ( Softawre is option) | |||||||
Temp. range | Maximum: 80 ºC,120 ºC; Minimum: -60 ºC, -50 ºC, -40 ºC, -30 ºC, -20 ºC, -10 ºC, 0 ºC |
|||||||
Humidity Range | 10%, 20%, 30% ~ 95% | |||||||
Temp. constancy | ±0.5 ºC | |||||||
Humidity constancy | ±2.5%R.H | |||||||
Temp. uniformity | ±2.0 ºC | |||||||
Humidity uniformity | ±5.0%R.H | |||||||
Ambient Temp. | +5 ºC~+35 ºC | |||||||
Wiring method | AC 380 ± 10% 50Hz ,3 phase 4 wires + Ground Wires | |||||||
Heat up time | +20 ºC~+80 ºC, Within 60 min | |||||||
Pull down time | +20 ºC ~ -55 º, -40 ºC, -20 ºC, -10 ºC, Within 120 or 90 or 60 min | |||||||
Interior material | Stainless Steel Plate(SUS 304) | |||||||
Exterior material | Baked Painting Steel Or Stainless steel ( SUS304) | |||||||
Insulation material | Rigid polyurethane foam | |||||||
Door size (mm) | Single wing: W800 x H1800; Double wing: W1600 x H1800; | |||||||
Note:1. We reserve the right to change specifications without prior notice 2.Customized sizes and configurations available |
Control method and characteristics:
Precision microcomputer control temperature and humidity system, with PID control the refrigerant flow to make the system’s heating / humidification reduction, to achieve low power consumption, energy saving, carbon reduction effect, cooling, heating, humidity control intelligent electronic control, long-term stable use.